Motors and Maintenance for Central Vac International
All Products for Central Vac International
Only hear a "click" when trying to start the system? Does it shut off and start back up in a few minutes? These are common signs of a dead motor which only leaves two options. Replace the motor or the replace unit. If you liked the amount of suction it originally had, then replace the motor. If you'd like stronger suction or if you'd like a cleaner disposal system consider a different unit or alternative brand.

How is a central vacuum maintained? Generally, the only thing required is emptying the main unit. Beyond that there are some upkeep and preventative options given below.
Replacement Chart for Central Vac International Vacuum Motors, Filtration, & More
Model # Replacement Motor
Filtration

CV7
CV-07
CVS-07
CVS-07DP
120 volt
Price / Details /
Instructions
116336
(replaces 119414 and 115757)
Paper Bag #722

CV11
CV-11
CVS-11
CVS-11DP
120 volt
Price / Details /
Instructions

117508
Paper Bag #722

CVS207
CVS207DP
220-240 volt
Price / Details /
Instructions

116110

Paper Bag #722

CV612, CV-612
Price / Details /
Instructions

116311
RV Model

CV9, CV9DP
120 volt
Not available from MD Vac Paper Bag #722

CV16, CVS16, CVS16DP, CV16DP
120 volt
Price / Details /
Instructions

116137
Paper Bag #722

C VS216, CVS216DP
220-240 volt
Not available from MD Vac Paper Bag #722

CVS219, CVS219DP
220-240 volt
Not available from MD Vac Paper Bag #722
Basic Maintenance for Central Vac International Vacuum

Filtration Maintenance
Much like a regular portable vacuum, the basic maintenance of a Central Vac International Central Vacuum System is changing the bag in the main unit. To do this, remove the top of the unit, remove the then lift the paper bag out and set it in the trash can. Put a new paper filter into the support filter. Below the support filter is a screen or filter that keeps large debris out of the motors if there was an accident with the main filter. Be sure this trap filter is basically clean.

Motor and Vacuum Maintenance
There is nothing to lube or oil in or on the central vacuum system, including the Central Vac International motor, Central Vac International vacuum motor unit, or Central Vac International vacuum cleaner. For the indoor vacuum brush, the fibers that get wrapped around the brush roll of the vacuum cleaner head should be cut out and removed on a regular basis.

Pipe and Hose Maintenance
We recommend cleaning out the hose and piping system at least once per year. The best way to do that is with Tornado Central Vacuum Maintenance Cloths. They do a couple of things. First, they push through the pipes, bringing along stalled out debris. Second, they deodorize the hose, pipes, and unit. Some amazing results can come from this product. The vacuum hose will last longer if it is stored on a hanger, always being detached from the vacuum after each use. See if any of these Storage Items can help your situation (scroll to the bottom of the Accessory Page).

Email Reminders to Empty Vacuum
Sign up for the Free Quarterly Email Reminders to dispose of your central vacuum debris. Let the trash build up can reduce suction, making the unit run hotter and clean less efficiently.

Replacement Motors and Parts for Central Vac International Vacuums

Troubleshooting
Self diagnose your system using this Interactive Troubleshooting Guide and Solutions.

Motor Replacement
Contact a local dealer for service, or consider doing it yourself. Motors on the Central Vac International vacuum have a few fasteners and wires that need to be unattached, the reattached on the new motor. It should take less than one hour. First, turn off the circuit breaker or unplug the central vacuum unit. Then, access the motor by releasing the outer housing. Use the chart to find the right replacement motor for your Central Vac International motor model. A motor may have many numbers on it but typically the real motor number starts with 11. Here are detailed Central Vac International Motor Replacement Instructions.

Circuit Board, Relay, Transformer, MiniBreaker
Separate transformers, relays, and minibreakers are not available here for Central Vac International. However, when a circuit board is installed, the most common board replacement for Central Vac International vacuums is the Vacuum Motor Circuit Board for Single Motor Units 110 Volt. The board is strong, yet generic and may need to be retrofitted. There are other Generic Circuit Boards here for units with different voltage and two motors. These robust generic boards are made by the leading industry supplier. An electrician will be able to replace the circuit board, or replace the relay, transformer, and minibreakers with a circuit board quite easily. Print and use the large photograph of the board as the wiring guide.

Motor Carbon Brush
The Central Vac International motor has two carbon brushes that wear down and can be replaced before they damage the motor. However, the Central Vac International motor may go bad for other reasons while the carbon brushes remain fine. Central Vac International motor brushes can be checked every few years and replaced if the 3/4-inch-long solid carbon is worn down. Definitely replace if one or both are down to 3/16 inch. Type the motor replacement number (not model number) in the search box and the motor brushes will come up along with instructions.
 
Note: Central Vac International Vacuum is a registered trademark of Central Vac International, not M.D. Manufacturing, Inc. Products sold by M.D. Manufacturing, Inc. are not from Central Vac International Vacuum but are designed to complement a Central Vac International Central Vacuum. Therefore, parts and products carry warranties from MD Manufacturing and not Central Vac International Vacuum and thus may alter the warranty provided by Central Vac International Vacuum.
Need more help? Try our extensive and helpful Central Vac International Vacuum Questions and Answers or give us a call at 1-800-997-2278 M-Th 7 a.m. to 5 p.m. Pacific Standard Time.