| Replacement Chart for Electrolux Vacuum Motors, Filtration, & More | ||
|---|---|---|
| PLEASE NOTE: if your original gasket is not a thin foam pad then REUSE your original gasket no matter what. |
||
| Unit Model # | Replacement Motor - USE ORIGINAL MOUNTS - |
Filtration Electrolux, Aerus no longer produces pleated paper filters. Use Foam Filter. |
Centralux, Electrolux 1580 110-120 volt |
![]() Price / Details / Instructions 116765, 6765 |
6"x6" Foam Filter #730EXF |
Electrolux Some 1590 (also see below) and ECV1590A and ECV1690A and E177A and E117A 110-120 volt |
![]() Price / Details / Instructions 116765, 6765 |
6"x6" Foam Filter#730EXF |
(*Motor is shorter than 116765 and has a tapered bottom.) |
Price / Details /Instructions 119631 (Replaces 6600-001 including HL10 P-9 ECD. Also, clip the wires from the old motor to splice into the new motor wires. Need wire nuts and possibly washers to make up 1/8" difference on bolt threads when tightening. NOTE: the bottom of the motor is not flat but tapers down over 1/2 inch. If your motor bottom is not tapered but completely flat, order 116472.) |
6"x6" Foam Filter#730EXF
|
Afuera 110-120 volt (Made by Beam.) |
![]() Price / Details / Instructions 116765 |
|
| Centralux 110-120 volt |
![]() Price / Details / Instructions 116765 |
6"x6" Foam Filter #730EXF |
| Electrolux CV3291, Electrolux CV3391a |
Not available from MD Vac |
|
Filtration Maintenance
Much like a regular portable vacuum, the basic maintenance of a Electrolux Central Vacuum System is changing the bag, or, in most cases, emptying the dirt receptacle on the main unit. To do this, remove the base of the unit with a twist or by unlatching, then dump the debris. If the unit has a foam filter, remove it and beat it out or wash it and completely air dry it. If the unit has a center weighted cloth filter, place a plastic trash bag over the bottom of the unit, reach up and grab the cloth filter and shake it. This filter can be further cleaned or replaced. To remove the filter, grab a side of it and pull toward the center. The outer stiff rim of the filter bends in and the filter drops out. To further clean the filter, wash it and thoroughly air dry before installing.
Pipe and Hose Maintenance
We recommend cleaning out the hose and piping system at least once per year. The best way to do that is with Tornado Central Vacuum Maintenance Cloths. They do a couple of things. First, they push through the pipes, bringing along stalled out debris. Second, they deodorize the hose, pipes, and unit. Some amazing results can come from this product. The vacuum hose will last longer if it is stored on a hanger, always being detached from the vacuum after each use. See if any of these Storage Items can help your situation (scroll to the bottom of the Accessory Page).
Email Reminders to Empty Vacuum
Sign up for the Free Quarterly Email Reminders to dispose of your central vacuum debris. Let the trash build up can reduce suction, making the unit run hotter and clean less efficiently.
Troubleshooting
Self diagnose your system using this Interactive Troubleshooting Guide and Solutions.
Circuit Board, Relay, Transformer, MiniBreaker 
Separate transformers, relays, and minibreakers are not available here for Electrolux. However, when a circuit board is installed, the most common board replacement for Electrolux vacuums is the Vacuum Motor Circuit Board for Single Motor Units 110 Volt. The board is strong, yet generic and may need to be retrofitted. There are other Generic Circuit Boards here for units with different voltage and two motors. These robust generic boards are made by the leading industry supplier. An electrician will be able to replace the circuit board, or replace the relay, transformer, and minibreakers with a circuit board quite easily. Print and use the large photograph of the board as the wiring guide.