| Replacement Chart for M & S Vacuum Motors, Filtration, & More | ||
|---|---|---|
| M & S Model # | M & S Replacement Motor | Paper Bag fits in Cloth Bag |
M&S FiltexFX2000 ZX5800 110-120 volt |
![]() Price / Details /Instructions 116472 |
![]() M and S FX-2000 Bag #722L |
M&S FiltexFX3000 ZX6000 110-120 volt |
![]() Price / Details / Instructions 116765 (replaces 116565) |
![]() M & S FX-3000 Bag #722L |
M&S FiltexFX4000 ZX7000 110-120 volt |
![]() Price / Details / Instructions 117500 |
M & S FX-4000 |
M&S FiltexFX5000 ZX8000 220-240 volt |
![]() Price / Details / Instructions 117500 |
M & S FX-5000 Bag #722L |
FX5800110-120 volt |
![]() Price / Details / Instructions 116472 |
|
FX6000110-120 volt |
![]() Price / Details / Instructions 116765 (replaces 116565) |
![]() M & S FX-6000 Bag #722L |
FX7000110-120 volt |
![]() Price / Details / Instructions 117500 |
![]() M and S FX-7000 Bag #722L |
FX8000110-120 volt |
Price / Details /
Instructions117500 |
|
110-120 volt |
![]() Price / Details / Instructions 116472 |
Cloth Filter Compare Inventory |
110-120 volt |
![]() Price / Details / Instructions 116765 (replaces 116565) |
Cloth Filter Compare Inventory |
110-120 volt |
![]() Price / Details / Instructions 117500 |
Cloth Filter Compare Inventory |
110-120 volt |
![]() Price / Details / Instructions 117500 |
Cloth Filter Compare Inventory |
Filtration Maintenance
Much like a regular portable vacuum, the basic maintenance of a M & S Central Vacuum System is changing the bag. To do this, remove the top of the unit, remove the then lift the paper bag out and set it in the trash can. Put a new paper filter into the support filter. Below the support filter is a screen or filter that keeps large debris out of the motors if there was an accident with the main filter. Be sure this trap filter is basically clean. For units without a disposable bag, empty the dirt receptacle on the main unit. To do this, remove the base of the unit with a twist or by unlatching, then dump the debris. Place a plastic trash bag over the bottom of the unit. Reach up and grab the center weighted cloth filter and shake it. This filter can be further cleaned or replaced. To remove the filter, grab a side of it and pull toward the center. The outer stiff rim of the filter bends in and the filter drops out. To further clean the filter, wash it and thoroughly air dry it before installing.
Pipe and Hose Maintenance
We recommend cleaning out the hose and piping system at least once per year. The best way to do that is with Tornado Central Vacuum Maintenance Cloths. They do a couple of things. First, they push through the pipes, bringing along stalled out debris. Second, they deodorize the hose, pipes, and unit. Some amazing results can come from this product. The vacuum hose will last longer if it is stored on a hanger, always being detached from the vacuum after each use. See if any of these Storage Items can help your situation (scroll to the bottom of the Accessory Page).
Email Reminders to Empty Vacuum
Sign up for the Free Quarterly Email Reminders to dispose of your central vacuum debris. Let the trash build up can reduce suction, making the unit run hotter and clean less efficiently.
Troubleshooting
Self diagnose your system using this Interactive Troubleshooting Guide and Solutions.
Circuit Board, Relay, Transformer, MiniBreaker 
Separate transformers, relays, and minibreakers are not available here for M & S. However, when a circuit board is installed, the most common board replacement for M & S vacuums is the Vacuum Motor Circuit Board for Single Motor Units 110 Volt. The board is strong, yet generic and may need to be retrofitted. There are other Generic Circuit Boards here for units with different voltage and two motors. These robust generic boards are made by the leading industry supplier. An electrician will be able to replace the circuit board, or replace the relay, transformer, and minibreakers with a circuit board quite easily. Print and use the large photograph of the board as the wiring guide.