Vacuum Motor Circuit Board Single Motor 15amp 120v
Contains relay, transformer, mini breaker (one 15 amp), and two pairs of low voltage leads.
Circuit board control module is 2" high from board to top of reset button. The reset button and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch female spade terminals are not included. See Q&A to the right for some more brand specific help.
|
|
|
Vacuum Motor Circuit Board Dual Motor 15 amp 120v
Contains relay, transformer, mini breakers (two 10 amp), and two pairs of low voltage leads.
Circuit board control module is 2" high from board to top of reset button. The reset buttons and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch male or female spade terminals are not included. See Q&A to the right for some more brand specific help.
|
|
|
Vacuum Motor Circuit Board Dual Motor 28 amp 120v
Contains relay, transformer, mini breakers (two 15 amp), and two pairs of low voltage leads.
Circuit board control module is 2" high from board to top of reset button. The reset button and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch female spade terminals are not included. See Q&A to the right for some more brand specific help.
|
|
|
Vacuum Motor Circuit Board Single Motor 7 amp 240v
Contains relay, transformer, mini breaker, ground, and two pairs of low voltage leads. Circuit board control module is 2" high from board to top of reset button. The reset button and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch female spade terminals are not included. See Q&A to the right for some more brand specific help.
|
|
|
Vacuum Motor Circuit Board Dual Motor 12 amp 240v
Contains relay, transformer, mini breaker, ground, and two pairs of low voltage leads. Circuit board control module is 2" high from board to top of reset button. The reset button and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch female spade terminals are not included. See Q&A to the right for some more brand specific help.
|
|
|
Vacuum Motor Circuit Board Dual Motor 18 amp 240v
Contains relay, transformer, mini breaker, ground, and two pairs of low voltage leads. Circuit board control module is 2" high from board to top of reset button. The reset button and low voltage stems are threaded and attach through openings in the vacuums exterior. External mounting nuts for these are included. Click on photo and print it to use as wire placement instructions. NOTE: This board does not work on all vacuums and quarter inch female spade terminals are not included. See Q&A to the right for some more brand specific help. Replaces older part number 236LX. (Back of board says 120 volt but it is 240 volt.)
|
|
|
Wire Set
The wire set can be helpful when installing a new motor or circuit board. Some motors such as 198A do not come with wires.
|
|
|
110 volt Transformer
Transformer used in some brands and models, such as: S2, B, B2, E2, QE2, S1, S4, C110, C95, M19, M32, M34, M72, M45. Click here to print a Wiring Diagram to use while installing - ALSO view diagrams from part #242.
|
|
|
110 volt Transformer (large)
Transformer used in some brands and models, such as: SV, SVT, S3, S5, C210, G23. Can also be used for smaller models. BUT NOTE this transformer must be used now with the only replacement relay we sell for all our vacuums. The #242 Relay must be used with the #232 Transformer. To wire correctly see the diagrams in #242 relay and note that you need to choose either the white or red or orange wire (white is for 110-120 volt units, Red is for 208 volt, and Orange is for 240 volt - these instructions are on a sticker on the top of the transformer).
|
|
|
240 volt Transformer
Transformer used in some brands and models, such as: S2, B, B2, E2, QE2, S1, S4, C110, C95, M19, M32, M34, M72, M45. Click here to print a Wiring Diagram to use while installing - ALSO view diagrams from part #242.
|
|
|
240 volt Transformer (large)
Transformer used in some brands and models, such as: SV, SVT, S3, S5, C210, G23. Click here to print a Wiring Diagram to use while installing - ALSO view diagrams from part #242. Depending on availability, you may receive either one of the transformers shown. Both transformers are used for the same application.
|
|
|
28 amp Relay (replaces relays, requires large transformer)
This relay replaces the smaller ones (#240 and #241) previously sold. It ONLY WORKS WITH LARGE TRANSFORMERS (PART #232 if 110-120 volt or #231L if 220-240 volt) which are typically are not in machines under 20 amps - regardless of what you read elsewhere on this website, this relay requires the larger transformer. You can replace your transformer. The 242 relay works with all kinds of 110 to 240 volt motors, and all minibreakers. It works with an electrical set-up similar to the ones in the following photographed diagrams. Click and print a diagram for wiring a SINGLE MOTOR VACUUM, or DUAL MOTOR VACUUM under 16 amps, or DUAL MOTOR VACUUM over 16 amps. (When in doubt on amps use the diagram for the larger amps.) Wires are not sold here. Use 14 or 16 gauge wires and put on 1/4 inch flag terminals (all available at hardware stores). Use 12 gauge wire for dual motor setups over 17 amps. To mount it you MUST HAVE 4 x 2.5 inches of space. Do not allow any metal on the relay (besides the bottom) to touch any metal parts on the vacuum except the wires. There are several "feet" on the bottom to use screws (not included) to secure it. #242 Replaces Omron Relays. Has MFG# DP2020A5021.
|
|
|
7 amp Mini Breaker
7 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 7 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI) This mini breaker replaces all other mini breakers.
|
|
|
7 amp Snap-in Minibreaker Reset
7 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 7 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI)
|
|
|
10 amp Mini Breaker
10 amp minibreaker for 110 volt and 240 volt vacuum units. The one the left (may have not come with imprinted ring originally) replaces most all types of 10 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V - not volts - "VAC" by MPI) This mini breaker replaces all other mini breakers.
|
|
|
10 amp Snap-in Minibreaker Reset
10 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 10 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI)
|
|
|
15 amp Mini Breaker
15 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 15 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI) This mini breaker replaces all other mini breakers.
|
|
|
15 amp Snap-in Minibreaker Reset
15 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 15 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI)
|
|
|
20 amp Mini Breaker
20 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 20 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI) This mini breaker replaces all other mini breakers.
|
|
|
20 amp Snap-in Minibreaker Reset
20 amp minibreaker for 110 volt and 240 volt vacuum units replaces most all types of 20 amp minibreakers such as snap-ins and square buttons. If the minibreaker is attached to a circuit board the entire board will need to be replaced. (250V -not volts- "VAC" by MPI)
|
|
|
Low Voltage Booster Box
Splice this booster into a vacuum's low voltage wiring system, plug it into 110 volts, and your 24 volt line will be boosted with plenty of juice! The two blue wires connect to your power unit low voltage (you can use speaker wire to extend any of the wire here) and the red and yellow (or two red) wires connect to the low voltage leads coming from the install site. Simply hang the box on your wall with a nail into a stud. Be sure to use wire nuts to get good connections when joining the wires together.
|
|
|
Low Voltage Toggle Switch
|
|
|
Low Voltage Rocker Switch
|
|
|
30 amp Receptacle (for S5 and SV 110 volt)
The plug is called a Nema 5-30 Socket or Plug (for units 110 volt over 20 amps). The large 110 volt plug goes into it. The plug is larger than 240 volt plugs and one prong looks like an "L". This socket fits into and can be used with a single gang box. This receptacle may be hard to find, therefore we suggest buying it along with the unit.
|
|
|
RFX Central Vac Wireless Remote Kit (not RF915)
This is the easiest way to bypass damaged low voltage wiring and remotely start your vacuum unit. Simply install the receiver near the vacuum unit and click the key fob to turn the suction on and off. Surprise - your low voltage wiring troubles are over. Range is similar to a vehicle key fob - about 150 feet depending on wall thickness and barriers. The powerful 400 mhz is sufficient for nearly all homes. Each receiver is programmed separately so you can have multiple systems in adjoining homes and condos. Extra key fobs sold separately. Not compatible with #145 LV11 parts. PDF of RFX Instructions
|
|
|
RFX Remote Clicker Key Fob Alone (not RF915)
Key fob remote for the #145 Wireless Controller for Central Vacuum Systems. You can have up to 15 key fobs per #145 receiver. To program, hold key fob button for 3 seconds, release; press and release the button on receiver once. Press the key fob button once and the vacuum will turn on. Press it again to turn it off. Not compatible with #145 LV11 parts or RF915. PDF of RFX Instructions
|
|
|
RF 915 Receiver - Radio Frequency
Use this receiver as part of the RF915 central vacuum wireless solution. Only one needed per home and is installed near the central vacuum unit. Connect to the central vacuum with low voltage wire. The receiver is also plugged into 110 volts. RF 915 INSTRUCTIONS (Word File)
|
|
|
RF 915 Hose Handle Wiring Harness - Radio Frequency
ONLY for use in a two wire electric hose from MD, and as part of the RF915 central vacuum control solution. Multiple RF915 hoses can be used in one home. Be sure there is 110 volts getting to the hose handle or this will not work. RF 915 INSTRUCTIONS (Word File)
|
|
|
RF 915 AutoMitter - Radio Frequency
Use this stand alone transmitter as part of the RF915 central vacuum wireless control solution. Connect any number of VacPans, low voltage valves of any kind using low voltage wire. Multiple can be used in a one home. The AutoMitter is battery operated so be sure it is accessible. RF 915 INSTRUCTIONS (Word File)
|
|
|
RF 915 Signal Repeater - Radio Frequency
RF915 signal repeater for large homes or homes with signal interference. Use one per home, if needed. Or two on separate sections of the home. They do not repeat a repeater's signal so they do no daisy chain. Program the repeater to the RF hose handle. RF 915 INSTRUCTIONS (Word File)
|
|