Skip to content
Shop Products

AirMaster XL Models Compared

AirMaster XL 240V Unit Specifications

See 120 V Units

A715h2

A715h2
Part # A2185LH

Suction Power

10,000 sq ft Covers
Single 2-stage 8.4" by-pass motor Motor
711 Max Air Watts
153.0 " Water Lift
134.0 CFM

Dirt Collection

Tru-Seal® Closed Bag System Filtration
8 Gallon Trash Capacity

Other Features

68 dB Noise Level
7.8 Max Amps
39.5" Tall
42 lbs
10 Year Warranty

A850h2Q

A850h2Q
Part # A2260NH

Suction Power

20,000 sq ft Covers
Single 3-stage 5.7" by-pass motor Motor
850 Max Air Watts
257.0 " Water Lift
92.0 CFM

Dirt Collection

Tru-Seal® Closed Bag System Filtration
8 Gallon Trash Capacity

Other Features

68 dB Noise Level
14.4 Max Amps
39.5" Tall
45 lbs
10 Year Warranty

A900r2Q

A900r2Q
Part # A2257NH

Suction Power

20,000 sq ft Covers
Dual 3-stage 5.7" by-pass motors Motor
866 Max Air Watts
136.0 " Water Lift
190.0 CFM

Dirt Collection

Tru-Seal® Closed Bag System Filtration
8 Gallon Trash Capacity

Other Features

64 dB Noise Level
13.7 Max Amps
39.5" Tall
45 lbs
10 Year Warranty

Specifications for all AirMaster XL units

  • Resettable Minibreaker Protection
  • 18 & 20 Gauge Steel Construction
  • Powder Coat Surface finish
  • Filtered Exhaust
  • Includes Dual intake valves
  • Includes Utility valve

AirMaster XL Warranty

M.D. Manufacturing, Inc. warrants its AirMaster power units against electrical component failure for a period of ten (10) years. This warranty is transferable with the unit and is not solely limited to the original owner. Any parts (excluding filters) required within the first ten years will be furnished free of charge by the Authorized Dealer from whom the power unit was originally purchased. In addition, all AirMaster units are guaranteed for life against defects in materials and workmanship.

If an Authorized Dealer is not nearby, M.D. Manufacturing, Inc. will honor and perform required warranty services. The end user must return the unit to the factory freight pre-paid. This warranty does not apply to applications outside of North America, commercial applications, misuse, abuse, acts of God, operating without the filters, or units tampered with by unauthorized personnel.


Exterior Venting: Venting is optional. Exterior venting is required for confined locations.

* The square foot coverage for a central vacuum should be based on factors including altitude, hours of use, complexity of pipe installation, length of furthest vacuum inlet, noise level desired, type and size of filtration, installation materials, and budget. The square footage recommendation on this page can be higher or lower when taking these factors into consideration.